-->

Mouse phospho-SLP-76 (Ser376) cellular kit HTRF®

The mouse phospho-SLP-76 (Ser376) kit enables the cell-based quantitative detection of mouse phosphorylated SLP-76 at Ser376, for monitoring T-lymphocyte activation.
Voir plus d’informations
  • Ready-to-use Ready-to-use
  • High sensitivity High sensitivity
  • Faster and more convenient than ELISA Faster and more convenient than ELISA
  • No-wash No-wash
The mouse phospho-SLP-76 (Ser376) kit enables the cell-based quantitative detection of mouse phosphorylated SLP-76 at Ser376, for monitoring T-lymphocyte activation.
-

Overview

This HTRF cell-based assay enables rapid, quantitative detection of mouse SLP-76 phosphorylated on Serine 376. Phospho-SLP-76 creates a scaffold on which key signaling complexes are built, and is a marker of T-lymphocyte activation.

Benefits

  • SPECIFICITY
  • PRECISION

Mouse phospho-SLP-76 (Ser376) assay principle

The Mouse phospho-SLP-76 (Ser376) assay measures mouse SLP-76 when phosphorylated at Ser376. Unlike Western Blot, the assay is entirely plate-based and does not require gels, electrophoresis, or transfer. The Mouse phospho-SLP-76 (Ser376) assay uses 2 labeled antibodies: one with a donor fluorophore, the other one with an acceptor. The first antibody was selected for its specific binding to the phosphorylated motif on the protein, and the second for its ability to recognize the protein independent of its phosphorylation state. Protein phosphorylation enables an immune-complex formation involving both labeled antibodies and which brings the donor fluorophore into close proximity to the acceptor, thereby generating a FRET signal. Its intensity is directly proportional to the concentration of phosphorylated protein present in the sample, and provides a means of assessing the protein’s phosphorylation state under a no-wash assay format.

Phospho-SLP-76 (Ser376) assay principle

Mouse phospho-SLP-76 (Ser376) 2-plate assay protocol

The 2 plate protocol involves culturing cells in a 96-well plate before lysis, then transferring lysates to a 384-well low volume detection plate before the addition of mouse phospho-SLP-76 (Ser376) HTRF detection reagents. This protocol enables the cells' viability and confluence to be monitored.

Phospho-SLP-76 (Ser376) 2-plate assay protocol

Mouse phospho-SLP-76 (Ser376) 1-plate assay protocol

Detection of mouse phosphorylated SLP-76 (Ser376) with HTRF reagents can be performed in a single plate used for culturing, stimulation, and lysis. No washing steps are required. This HTS designed protocol enables miniaturization while maintaining robust HTRF quality.

Phospho-SLP-76 (Ser376) 1-plate assay protocol

Function and regulation of SLP-76

TCR engagement promotes the phosphorylation of immunoreceptor tyrosine-based activation motifs (ITAMs) on the cytosolic side of the TCR/CD3 complex by lymphocyte protein tyrosine kinase (Lck). Zap-70 is recruited to the TCR/CD3 complex, where it becomes phosphorylated and activated. ZAP-70 phosphorylates SLP-76. Activated SLP-76 translocates to the plasma membrane and promotes a multi-protein complex, which participates in the activation, survival, and proliferation of T-Lymphocytes.
Simplified pathway of SLP-76

HTRF cellular phospho-protein assays

physiologically relevant results fo fast flowing research - Flyers

Best practices for analyzing brain samples with HTRF® phospho assays for neurosciences

Insider Tips for successful sample treatment - Notes techniques

Optimize your HTRF cell signaling assays on tissues

HTRF and WB compatible guidelines - Notes techniques

Best practices for analyzing tumor xenografts with HTRF phospho assays

Protocol for tumor xenograft analysis with HTRF - Notes techniques

Key guidelines to successful cell signaling experiments

Mastering the art of cell signaling assays optimization - Guides

HTRF® cell signaling platform combined with iCell® Hepatocytes

A solution for phospho-protein analysis in metabolic disorders - Posters

HTRF phospho-assays reveal subtle drug-induced effects

Detailed protocol and direct comparison with WB - Posters

Universal HTRF® phospho-protein platform: from 2D, 3D, primary cells to patient derived tumor cells

Analysis of a large panel of diverse biological samples and cellular models - Posters

HTRF phospho assays reveal subtle drug induced effects in tumor-xenografts

Tumor xenograft analysis: HTRF versus Western blot - Notes d'application

HTRF cell-based phospho-protein data normalization

Valuable guidelines for efficiently analyzing and interpreting results - Notes d'application

HTRF phospho-total lysis buffer: a universal alternative to RIPA lysis buffers

Increased flexibility of phospho-assays - Notes d'application

HTRF Alpha-tubulin Housekeeping kit

Properly interpret your compound effect - Notes d'application

Simplified pathway dissection with HTRF phospho-assays and CyBi-felix liquid handling

Analyse of PI3K/AKT/mTor translational control pathway - Notes d'application

How to run a cell based phospho HTRF assay

What to expect at the bench - Vidéos

Unleash the potential of your phosphorylation research with HTRF

A fun video introducing you to phosphorylation assays with HTRF - Vidéos

How to run a cell based phospho HTRF assay

3' video to set up your Phospho assay - Vidéos

Cisbio Product Catalog 2019

All your HTRF assays in one document! - Catalogue

A guide to Homogeneous Time Resolved Fluorescence

General principles of HTRF - Guides

How HTRF compares to Western Blot and ELISA

Get the brochure about technology comparison. - Brochures

Advance your research on Fibrosis

Kits and reagents for Fibrosis research - Flyers

Guidelines for Cell Culture and Lysis in Different Formats Prior to HTRF Detection

Seeding and lysing recommendations for a number of cell culture vessels. - Notes techniques

Assessment of drug efficacy and toxicity by combining innovative technologies

Combination of AlphaLISA®, HTRF®, or AlphaLISA® SureFire® Ultra™ immunoassays with the ATPlite™ 1step cell viability assay - Notes d'application

Methodological Aspects of Homogeneous Time-Resolved Fluorescence (HTRF)

Learn how to reduce time and sample consumption - Notes d'application

Manual SLP76 P-S376 (m) Kit / 63adk109peg-63adk109peh

63adk109peg-63adk109peh - Protocoles

Certificate of Analysis SLP76 P-S376 (m) Kit / 63ADK109PEG

63ADK109PEG Lot 03C - Rapports de contrôle qualité

Plate Reader Requirement

Choosing the right microplate reader ensures you’ll get an optimal readout. Discover our high performance reader, or verify if your lab equipment is going to be compatible with this detection technology.

Let's find your reader